Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Biosci. j. (Online) ; 30(1): 182-193, jan./feb. 2014. graf, ilus
Article in Portuguese | LILACS | ID: biblio-946988

ABSTRACT

Objetivou-se com este trabalho, estudar o efeito do déficit de pressão nos parâmetros da pulverização da ponta JA-2 em diferentes alturas do alvo, e discutir suas implicações na evaporação das gotas da pulverização. Para estudar os parâmetros da pulverização utilizaram-se etiquetas de papel hidrossenssível, fixadas em suportes de madeira a 0,5, 1,5 e 2,5 metros de altura, utilizando um pulverizador hidropneumático acoplado a um trator John Deere. O experimento foi montado em esquema fatorial (3 x 13), sendo três déficits de pressão de vapor e 13 pressões de pulverização com três repetições no delineamento de blocos casualizados. Os resultados indicaram que o aumento do déficit de pressão de vapor d'água no ar afetou a pulverização, reduzindo o tamanho de gotas. A altura do alvo influenciou nos parâmetros do espectro de gotas da pulverização. A percentagem de cobertura do alvo teve um aumento com o incremento do déficit de pressão de vapor d'água no ar e da pressão de trabalho. A densidade de gotas aumentou com a pressão de trabalho e reduziu com o déficit de pressão de vapor d'água no ar. A amplitude relativa foi maior com o aumento da pressão de trabalho e menor com o aumento do déficit de pressão de vapor d'água no ar.


The objective of this study was to evaluate the effect of pressure deficit on spraying parameters for the tip JA-2 at different target heights, and discuss its implications on the evaporation of spray droplets. To study the spray parameters, water-sensitive papers were fixed to a wood frame measuring 0.5 x 1.5 meters and 2.5 meters high, and a hydropneumatic sprayer was used attached to a John Deere tractor. The experiment was setup in a factorial design (3 x 13), consisting of three vapor pressure deficits and 13 spray pressures with three replications in a randomized block design. The results indicated that the increased vapor pressure deficit in the air affected spraying by reducing the droplet size. Height of the target influenced the spectral parameters of the spray droplets. The coverage percentage of the target increased with increases in the vapor pressure deficit in the air and working pressure. Droplet density increased with pressure and decreased with vapor pressure deficit in the air. The relative amplitude was greater with increasing working pressure and smaller with increasing vapor pressure deficit in the air.


Subject(s)
Agrochemicals , Drug and Narcotic Control , Vapor Pressure
2.
Biosci. j. (Online) ; 29(3): 667-675, may/june 2013. ilus
Article in English | LILACS | ID: biblio-914600

ABSTRACT

Air flow is of great importance in pneumatic sprayers as it is related to droplets sprayed size. Currently, there is a deficiency in regulating air flow in these sprayers. This work aimed to develop a system to control air flow of a pneumatic sprayer (Berthoud), and evaluate, in relation to air flow, power demanded by PTO and technical parameters of spraying (VMD, coefficient of homogeneity, percent coverage and droplets density), related to air flow. The diaphragm valve was projected using the software CAD, which was later made in galvanized steel and fixed to the fan air inlet. Air flow and power demanded on PTO was evaluated in eight diaphragm aperture positions (100, 90, 80, 70, 60, 50, 40 and 30%), and also using water sensitive papers, parameters of spraying were evaluated through a range of 30 meters in five diaphragm apertures (100, 90, 80, 70 and 60%). At the end it was found that between aperture of 100 and 70%, the closing of diaphragm caused a decrease of 4.56% in air flow. From aperture of 60%, reduction of air flow was more evident, resulting in reductions in air flow of 14.08, 24.00, 35.37 and 47.09% for opening levels 60, 50 , 40 and 30% of diaphragm, respectively. The power demand decreased linearly as diaphragm was closed. The system proved to be efficient to control spraying parameters with reduction of air flow, it has also increased droplet size (VMD), therefore resulted in reducing droplets density. Coverage percentage was influenced only by distance, reducing it as distance from the spray nozzle increased. The coefficient of homogeneity decreased as increased air flow and distanced from the spray nozzle.


Nos pulverizadores pneumáticos, a vazão de ar é de grande importância uma vez que está relacionado ao tamanho das gotas pulverizadas. Atualmente, verifica-se que existe a deficiência na regulagem da vazão de ar, nestes equipamentos. Sendo assim objetivou-se com este trabalho desenvolver um sistema de controle de vazão de ar em um pulverizador pneumático (Berthoud) e avaliar quanto à vazão de ar, potência exigida na TDP, e os parâmetros técnicos da pulverização (DMV, coeficiente de homogeneidade, porcentagem de cobertura e densidade de gotas). Projetou-se o diafragma com o auxilio do programa computacional CAD e que posteriormente foi confeccionado em aço galvanizado e fixado na entrada de ar do ventilador. Avaliaram-se as vazões de ar e a potência exigida pela TDP em oito posições de abertura do diafragma (100; 90; 80; 70; 60; 50; 40 e 30%), e também, com o auxílio de etiquetas hidrosenssíveis, avaliou os parâmetros da pulverização, ao longo de uma faixa de 30 metros em cinco aberturas do diafragma (100; 90; 80; 70 e 60%). Ao final verificou-se que entre as aberturas de 100 e 70%, o fechamento do diafragma promoveu um decréscimo de 4,56% na vazão de ar. A partir da abertura de 60%, a redução da vazão de ar foi mais evidente, obtendo-se reduções na vazão de ar de 14,08; 24,00; 35,37 e 47,09% para as aberturas de 60, 50, 40 e 30% do diafragma, respectivamente. Quanto à exigência de potência, este reduziu linearmente à medida que se fechou o diafragma. O sistema demonstrou ser eficiente no controle dos parâmetros da pulverização, com a redução da vazão de ar, aumentou o tamanho das gotas pulverizadas (DMV), consequentemente acarretou na redução da densidade de gotas. A porcentagem de cobertura foi influenciada somente pela distância, reduzindo-o conforme se distanciou do bocal do pulverizador. O coeficiente de homogeneidade reduziu à medida que aumentou a vazão de ar e se distanciou do bocal do pulverizador.


Subject(s)
Pesticides , Technology , Agrochemicals
SELECTION OF CITATIONS
SEARCH DETAIL